Not automatically, and anyone who says so without opening devices is skipping the assessment. Aluminum branch wiring from the late 1960s and 1970s fails at connections, not mid-run, and the approved remedies work at the connections: devices rated for aluminum, or copper pigtails with listed connectors installed by an electrician, at a fraction of whole house rewiring. The evidence that decides is at the devices: overheated, discolored, or loose aluminum connections argue for the full remedy program; clean, tight, properly rated connections argue for a monitored plan. Get the device level findings in writing either way.